4 buffer memory, Buffer memory, 57 for det – MITSUBISHI ELECTRIC 700 Series User Manual

Page 62

Advertising
background image

57

Buffer Memory

2

CC-

L

in

k CO

M

M

UNICAT

ION

2.4 Buffer Memory

2.4.1

Remote output signals

(Master module to inverter(FR-A7NC))

•Input states to the remote device station are stored.

•Two words are used for each station.

(Do not use address 16n (n = 2(X - 1) + 1, X = station No.))

Correspondences between Master Station Buffer Memory Addresses and Station

Numbers

Station

No.

Buffer

Memory

Address

Station

No.

Buffer

Memory

Address

Station

No.

Buffer

Memory

Address

Station

No.

Buffer

Memory

Address

1

160

H

17

180

H

33

1A0

H

49

1C0

H

2

162

H

18

182

H

34

1A2

H

50

1C2

H

3

164

H

19

184

H

35

1A4

H

51

1C4

H

4

166

H

20

186

H

36

1A6

H

52

1C6

H

5

168

H

21

188

H

37

1A8

H

53

1C8

H

6

16A

H

22

18A

H

38

1AA

H

54

1CA

H

7

16C

H

23

18C

H

39

1AC

H

55

1CC

H

8

16E

H

24

18E

H

40

1AE

H

56

1CE

H

9

170

H

25

190

H

41

1B0

H

57

1D0

H

10

172

H

26

192

H

42

1B2

H

58

1D2

H

11

174

H

27

194

H

43

1B4

H

59

1D4

H

12

176

H

28

196

H

44

1B6

H

60

1D6

H

13

178

H

29

198

H

45

1B8

H

61

1D8

H

14

17A

H

30

19A

H

46

1BA

H

62

1DA

H

15

17C

H

31

19C

H

47

1BC

H

63

1DC

H

16

17E

H

32

19E

H

48

1BE

H

64

1DE

H

RY F to RY 0
RY 1F to RY 10

RY11F to RY110

RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY 5F to RY 50
RY 6F to RY 60

RY 7F to RY 70
RY 8F to RY 80
RY 9F to RY 90

RY AF to RY A0
RY BF to RY B0
RY CF to RY C0

RY DF to RY D0
RY EF to RY E0

RY FF to RY F0

RY10F to RY100

RY7CF to RY7C0
RY7DF to RY7D0

RY7EF to RY7E0
RY7FF to RY7F0

Remote inputs (RY)

160

H

161

H

162

H

163

H

164

H

165

H

166

H

167

H

168

H

169

H

16A

H

16B

H

16C

H

16D

H

16E

H

16F

H

170

H

171

H

172

H

1DB

H

1DC

H

1DD

H

1DE

H

1DF

H

to

Addresses

For station
No.1

For station
No.63

Master Station

Remote device station

(Station No. 1: 1 station occupied)

X3F to X30

Inverter

RY 0F to RY 00

FR-A700 series

For station
No.2

For station
No.3

For station
No.4

For station
No.5

to

For station
No.6

For station
No.7

For station
No.8

For station
No.9

For station
No.64

Advertising