CC-Link I/O Specifications

2

CC-

L

in

k CO

M

M

UNICAT

ION

("n" indicates a value determined according to the station number setting.)
*1

Signal names are initial values. Using Pr. 180 to Pr. 186, Pr. 188, and Pr .189, you can

change input signal functions.

Signals of the RYn0, RYn1, and RYn9 can not be changed. Even when changed using Pr.

178, Pr. 179, and Pr. 187, the settings are invalid.

Refer to the inverter manual (applied) for details of Pr. 178 to Pr.189.

*2

Signal names are initial values. Using Pr. 190 to Pr .196, you can change output signal

functions.

Refer to the inverter manual (applied) for details of Pr. 190 to Pr.196.

(2) Remote resister

("n" indicates a value determined according to the station number setting.)

(3) Data I/O image

RY(n+1)B

to

RY(n+1)F

Reserved

RX(n+1)B

Remote station Ready

RX(n+1)C

to

RX(n+1)F

Reserved

PLC function

device No.

Address

Description

PLC function

device No.

Address

Description

D9062

RWwn

Registers designed to
read data received
from the master
station

D9078

RWrn

Registers designed to
write data to be sent
to the master station.

D9063

RWwn+1

D9079

RWrn+1

D9064

RWwn+2

D9080

RWrn+2

D9065

RWwn+3

D9081

RWrn+3

REMARKS

Use the remote registers freely since they are all user areas.

PLC

function

device

No.

Remote

output
device

No.

Signal

PLC

function

device

No.

Remote

input

device

No.

Signal

Devices in CC-Link (station No. 1)

RY00 to 0F

RX00 to 0F

RWw0

RWw1

RWw2

RWw3

RWr0

RWr1

RWr2

RWr3

Devices in built-in sequence

X30 to 3F

Y30 to 3F

D9062

D9063

D9064

D9065

D9078

D9079

D9080

D9081

Automatically refreshed at every END.

FR-A700 series