Setting of Output (Y) Status at Switching from

STOP Status to RUN Status

3.18 Setting of Output (Y) Status at Switching from

STOP Status to RUN Status

When the RUN status is switched to the STOP status, the outputs (Y) in the RUN
status are stored into the built-in PLC function.
Using the built-in PLC function parameter, you can set whether the outputs (Y) will be
output again or will be output after execution of operation when the STOP status is
switched to the RUN status.

"Output (Y) status at STOP is output"

The sequence program operation is performed after the output (Y)
status at the time of entering the STOP status is output.

"Outputs (Y) are cleared (output one scan later)"

The outputs (Y) are all cleared, and after execution of the sequence
program operation, the outputs are provided.

Fig 3.24 Processing Performed when STOP Status Is Switched to RUN Status

Output (Y) status at the time of

entering the STOP status is output.

Sequence program operation is executed.

STOP status to RUN status

Is output (Y) status at

STOP to be output?

Output (Y) status is cleared.

YES

NO