Prior to Sequence Program Creation

1.5 Prior to Sequence Program Creation

1.5.1

Precautions for sequence program creation

If any of the instructions (refer to page 103) and devices (refer to page 3) that cannot
be used with the built-in PLC function exists in a sequence program, an instruction
code error occurs at the execution of that instruction.
Error code

D9008=10

Operation error step

D9010

D9011

1.5.2

Usable main GX Developer functions

z

Parameter or sequence program read/write

z

Ladder monitor

z

Device monitor

z

Device test

z

All device memory clear

z

Remote RUN/STOP

POINT

Online change of the sequence program and access to other stations are not

allowed.
In addition, program read/write from other stations and all PLC memory clear
cannot be performed.

Back up the ladder configured with the protective function of GX Developer.

REMARKS

Refer to page 22 for the error codes.

CAUTION

Device test ([Online] - [Debug] - [Device test]) of GX Developer can be performed, but if

devices corresponding to control terminal (e.g. STF, STR) signals are tested, the

devices turn on in the sequence but the inverter does not perform the corresponding

operation.