2 internal relay (m) device map, 3 data register (d) device map, 4 special relays – MITSUBISHI ELECTRIC 700 Series User Manual

Page 17: Internal relay (m) device map, Data register (d) device map, Special relays

Advertising
background image

12

Device Map

1.6.2

Internal relay (M) device map

1.6.3

Data register (D) device map

1.6.4

Special relays

The special relays are internal relays with special applications and therefore should
not be switched on-off in the program.

Device No.

Description

M0 to M63

Use freely on user side.

Data

Register (D)

Inverter Pr.

Number

Parameter Name

Reference

Page

D0 to D99

Use freely on user side.

D100 to D119

Pr.506 to

Pr.515

User parameters. Use freely on user side.

38

Number

Name

Description

M9008

Self-diagnostic error

Turned on by self-diagnosed error.

M9010

Operation error flag

Turned on by an instruction execution error.
Turned off when error is removed.

M9011

Operation error flag

Turned on by an instruction execution error.
Remains on after normal status is restored.

M9036

Normally ON

M9036 and M9037 are turned on and off independently
of STOP or RUN.
M9038 and M9039 change depending on the STOP or
RUN status. In other than the STOP status, M9038 is on
for one scan only and M9039 is off for one scan only.

M9037

Normally OFF

M9038

On only for 1 scan after
RUN

M9039

Off only for 1 scan after
RUN

M9200

Inverter operation status
control flag (STF)

Control the STF terminal of the inverter from PLC
function

M9201

Inverter operation status
control flag (STR)

Control the STR terminal of the inverter from PLC
function

M9202

Inverter operation status
control flag (RH)

Control the RH terminal of the inverter from PLC
function

M9203

Inverter operation status
control flag (RM)

Control the RM terminal of the inverter from PLC
function

M9204

Inverter operation status
control flag (RL)

Control the RL terminal of the inverter from PLC function

M9205

Inverter operation status
control flag (JOG)

Control the JOG terminal of the inverter from PLC
function

M9206

Inverter operation status
control flag (RT)

Control the RT terminal of the inverter from PLC function

M9207

Inverter operation status
control flag (AU)

Control the AU terminal of the inverter from PLC
function

M9208

Inverter operation status
control flag (CS)

Control the CS terminal of the inverter from PLC
function

M9209

Inverter operation status
control flag (MRS)

Control the MRS terminal of the inverter from PLC
function

M9210

Inverter operation status
control flag (STOP)

Control the STOP terminal of the inverter from PLC
function

Advertising