4 timers t, 5 100ms, 10ms and 100ms retentive timers, Timers t – MITSUBISHI ELECTRIC 700 Series User Manual

Page 85: 100ms, 10ms and 100ms retentive timers

Advertising
background image

80

Description of devices

3.9.4

Timers T

The timers of the PLC function are count up timers.
The count up timer starts timing the present value when its coil turns on, and the
contact of that timer turns on when the present value reaches the setting (time-out).

3.9.5

100ms, 10ms and 100ms retentive timers

(1) 100ms and 10ms timers

The timer starts timing the present value when its coil turns on, and the present
value is reset to 0 and the contact turns off when the coil turns off.

Fig 3.15 Timing Chart

Ladder example

Timing chart

REMARKS

100ms, 10ms and 100ms retentive timers can be changed using the built-in PLC function
parameter. (The default is a 100ms timer.)
Since the FR-C500 has 8 timers (T0 to T7), it can use only any one type of 100ms, 10ms and
100ms retentive timers.

When input X5 turns on, T2 coil turns on
and timer times 5s. (T2 is 100ms timer.)

Setting

ON

5s

OFF

T2 contact

Timer present
value

T2 coil

X5

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

ON