Parallel program load operation, Parallel program load configuration figure 16–3, Parallel program load cycles figure 16–4 – Mitsubishi Motors DS5000TK User Manual

Page 141

Advertising
background image

USER’S GUIDE

050396 140/173

141

PARALLEL PROGRAM LOAD OPERATION

The DS5000 Parallel Program Load mode is compatible
with the Program mode of the 87C51. The hardware
configuration used for this mode of operation is shown in

Figure 16–3. Dallas Semiconductor recommends the
use of the serial Program Load Mode over the Parallel
Program Load Mode because of the ease of imple-
mentation and simpler hardware interface.

PARALLEL PROGRAM LOAD CONFIGURATION Figure 16–3

ALE/PROG

PSEN

RST

D7–D0

A15–A12

PROGRAM ADDRESS

PROGRAM DATA IN/
VERIFY DATA OUT

A7–A0

A11–A8

PROGRAM
ADDRESS

PROGRAM
CONTROL

V

CC

GND

DS5000

P1.7–
P1.0

P2.3–
P2.0

EA/V

PP

P2.7

P2.6

P2.5

XTAL1

XTAL2

P0.7–

P0.0

P3.7–

P3.4

PARALLEL PROGRAM LOAD CYCLES Figure 16–4

ALE/PROG

ADDRESS

DATA IN

ADDRESS

DATA OUT

PROGRAM CYCLE

VERIFY CYCLE

SECURITY SET

CYCLE

P2.3–P2.0
P1.7–P1.0

PORT 0

EA/V

PP

P2.7

P2.6

V

PP

V

IH

Advertising