a Partitionable mode (PM=0), the DS5001 can use up
to 64K x 8 SRAM for program and data on its Byte–wide
bus. It can partition this area into program and data
segments on 4K boundaries. The 64K memory space
would consist of two 32K x 8 SRAMs. Each is accessed
by a separate chip enable (CE1 and CE2), but the mi-
crocontroller automatically decodes which is needed.
While the DS5001 can use between one 8K x 8 SRAM
and 4 32K x 8 SRAMs, it does not automatically know

which configuration is used. The Range function deter-
mines how much total memory is connected to the
Byte–wide bus. The user must identify the total RAM
size using the Range bits RG1 and RG0. RG1 is lo-
cated at MCON.3 and RG0 is located at RPCTL.0.
These Range bits are selected during the Bootstrap
Loading process and can not be modified by the ap-
plication software. The Table below shows the Range
values that can be selected when PM=0 (Partitionable).

RG1

RG0

RANGE

CE1 ACCESS

CE2 ACCESS

1

1

64K

0000–7FFFh

8000–FFFFh

1

0

32K

0000–7FFFh

NA

0

1

16K

0000–1FFFh

2000h–3FFFh

0

0

8K

0000–1FFFh

NA

The total RAM space is partitionable, regardless of
which Range is selected. This contrasts with the
DS5000 that allowed partitioning of CE1 only. The
Partition table is shown below. PA3–0 are the four MSBs
of the MCON register (MCON.7–4). Note that the Parti-
tion values do not scale depending on Range. That is, if

a Range of less than 64K is selected, then the partition
settings above the Range should not be unused. The
microcontroller automatically decodes which RAM to
enable, and uses the Partition to decide if this is pro-
gram memory or data memory.

PA3

PA2

PA1

PA0

PARTITION

BYTE–WIDE BUS MEMORY MAP

0

0

0

0

0000h

0K PROGRAM, DATA = RANGE

0

0

0

1

1000h

4K PROGRAM, DATA = RANGE – 4K

0

0

1

0

2000h

8K PROGRAM, DATA = RANGE – 8K

0

0

1

1

3000h

12K PROGRAM, DATA = RANGE – 12K

0

1

0

0

4000h

16K PROGRAM, DATA = RANGE – 16K

0

1

0

1

5000h

20K PROGRAM, DATA = RANGE – 20K

0

1

1

0

6000h

24K PROGRAM, DATA = RANGE – 24K

0

1

1

1

7000h

28K PROGRAM, DATA = RANGE – 28K

1

0

0

0

8000h

32K PROGRAM, DATA = RANGE – 32K

1

0

0

1

9000h

36K PROGRAM, 28K DATA

1

0

1

0

A000h

40K PROGRAM, 24K DATA

1

0

1

1

B000h

44K PROGRAM, 20K DATA

1

1

0

0

C000h

48K PROGRAM, 16K DATA

1

1

0

1

D000h

52K PROGRAM, 12K DATA

1

1

1

0

E000h

56K PROGRAM, 8K DATA

1

1

1

1

FFFFh

64K PROGRAM, 0K DATA

Figure 4–5 illustrates the functional memory map of a
DS5001 series device in Partitionable mode. Note that
like the DS5000, any access that does not correspond

to a Byte–wide bus location is routed to the Expanded
bus Ports 0 and 2.