The time, calendar, and alarms are controlled by the
information in these 14 registers. In particular, the Com-
mand register controls most functions. This is described
in Figure 17–8. There are two additional bits that
deserve mention. These reside in the register at
address 09h. Bit 7 is EOSC, which enables the Time-
keeping oscillator if set to a 0. Battery lifetime can be
preserved by disabling the oscillator when it is not
needed and power is not present. Note the user’s soft-

ware should enable the oscillator, as it should be off for
shipping. If the oscillator is off, a user can read or write
to the Timekeeping register, but the time value will not
change. Bit 6 of the same register is the ESQW bit. This
controls the timekeeper 1024 Hz SQW output. The
SQW signal is available on the DS2251T. When it is
enabled, it drives a square wave of 1024 Hz. When dis-
abled, it is tri–state so it will not interfere with other uses
of a port pin.

DS1283 REAL–TIME CLOCK COMMAND REGISTER Figure 17–8

RTC COMMAND Register Address 0BH

TE

IPSW

IBH/L0

PU/LVL

WAM

TDM

WAF

TDF

CMD.7:

TE

Transfer Enable

To avoid updating of time registers while a read is taking place, the update
may be frozen. Setting the TE bit to a logic 0 will prevent an update of the
user–readable registers from the actual time of day. Setting TE to a logic 1
will enable updates every 0.01 seconds.

CMD.6:

IPSW

Interrupt Switch

When set to a logic 1, INTP will be assigned to time of day alarm and INTB
will be assigned to the periodic time–out. When set to a logic 0, the functions
are reversed.

CMD.5:

IBHL

INTB H/L

When set to logic 1, the INTB will source current (active high). When set to a
logic 0, INTB will sink current (active low).

CMD.4:

PU/LVL

Pulse/Level

When set to a logic 1, INTP will sink current for approximately 3 ms when it is
activated. INTB will sink or source (as set by IBLH) for 3 ms. When set to a
logic 0, the interrupt pins will signal with a continuous level.

CMD.3:

WAM

Watchdog Alarm

When set to a logic 1, the watchdog countdown timer interrupt will be

Mask

disabled. When set to a logic 0, the countdown interrupt is enabled.

CMD.2:

TDM

Time of Day

When set to a logic 1, the time of day interrupt is disabled. When set to a

Alarm Mask

logic 0, the time of day alarm is enabled.

CMD.1:

WAF

Watchdog

This bit will be set to a logic 1 by the DS1283 when a watchdog time–out

Alarm Flag

occurs. WAF is reset by reading or writing either of the countdown registers.

CMD.0:

TDF

Time of Day

This bit is set to a logic 1 by the DS1283 when a time of day alarm occurs. It is

Alarm Flag

cleared by reading or writing any time of day alarm register (register 3, 5, or 7).