Mvip electrical termination requirements – Interphase Tech RAS Communications Controller 5536 User Manual

Page 43

Advertising
background image

Chapter 2: Installing the Hardware

5536 PRI RAS Communications Controller Users Guide

23

For optimal electrical signal quality on the MVIP ribbon cable,
you must place the MVIP boards in a specific order (depending
on the number of connections) and electrically terminate two
MVIP clock signals, as described in the following topics.

MVIP Electrical Termination Requirements

For systems with five or fewer MVIP Bus connections and less
than 90 pF load on the clock lines, it is adequate to do the
following:

1. Place the circuit board that is the master clock source at

one end of the cable.

2. Electrically terminate the MVIP Bus only on the circuit

board located at the other end of the cable.

N

OTE

An 5536 board is generally the master clock source
because it is connected to the network. In this case, place
an 5536 board at one end of the cable, and do not
electrically terminate the bus on this board.

On systems with more than five MVIP Bus connections or
more than 90 pF of load on the clock lines, both ends of the
cable must be electrically terminated. No other boards should
be electrically terminated.