Chapter 3: Connecting to the Line

5536 PRI RAS Communications Controller Users Guide

29

Connecting Directly in a DSX1 Configuration

You can connect the board directly to the T1/PRI line without
using a CSU if the distance to your carrier is less than 655 feet
or 200 meters. The line will be in a DSX1 configuration, as
shown in the following illustration:

Figure 3-1. Direct DSX1 Connection to the Line

Connecting Directly in a DS1 Configuration

If the distance to your carrier is up to 6200 feet (1.8
kilometers), you can connect directly to the T1/PRI line with
the board’s internal CSU activated. The line will be in a DS1
configuration, as shown in the following illustration:

Figure 3-2. Direct DS1 Connection with Internal CSU

Connecting Through an External CSU to the Line

If you do not use the board’s internal CSU to connect to the
T1/PRI line in a DS1 configuration, you can connect the board
to an external CSU that connects to the metallic T1/PR1
interface. (You might want to use this method if the distance to

WAN Adapter

Telco

Less than 655 feet (200m)

WAN Adapter

Telco

Up to 6200 feet (1.8 km)