T1/PRI Line

30

Interphase Corporation

your carrier exceeds 6200 feet or 1.8 kilometers but is less than
6855 feet or 2.0 kilometers.) The following illustration shows
a connection to the T1/PRI line through an external CSU:

Figure 3-3. DS1 Connection Through an External CSU

W

ARNING

To avoid harming the WAN, you must first contact your
carrier for approval before connecting the CSU to the line.

C

AUTION

In accordance with FCC Rules, Part 68.218 (b), you must
notify the telephone company prior to disconnecting
the
CSU from the line or turning the CSU’s power off. Without
this prior notification, the carrier might temporarily
discontinue your T1/PRI service.

WAN Adapter

Telco

Up to 6200 feet (1.8 km)

CSU

Less than 655 feet (200m)