Table 5-3. error display – Seiko Group TM-L60 User Manual

Page 27

Advertising
background image

Table 5-3. Error Display

Error

RAM check error

ON/OFF Timing Pattern

Recovery

150

ms

Impossible to recover.

ON

OFF

150 ms

Transistor error

150 ms

1800

ms

Impossible to recover.

O N

O F F

300

ms

150 ms

Power supply, high

150 ms

1500

ms

impossible to recover.

voltage error

O N

(Power supply should

be inspected.)

OFF

150 ms 300 ms

150 ms

Power supply, low

150 ms

1200 ms

impossible to recover,

voltage error

O N

(Power supply should

be inspected.)

OFF

150

ms

300

ms

150

ms

Print head thermistor

150 ms

900 ms

Impossible to recover.

error

O N

OFF

150 ms

300 ms

150

ms

Internal data

Recovered by turning

processing error

150 ms

O N

the power off and on.

OFF

150 ms

1950 ms

Print head paper

Recovered by closing

out error

150 ms

ON

the cover after

inserting paper.

O F F

150 ms

1650 ms

21