6. Electrical characteristics

Supply voltage:

24 VDC ± 7% (Optional power supply:

PS-130)

Current consumption:

Operating:

Mean:

Approx. 1.3 A

(Print duty: 30%)

Peak:

Approx. 6.0 A

(Print duty: 100%)

Stand-by:

Approx.

100 mA

7.

EMI (by using Epson PS-130)

The cables using a shielded wire are used.

FCC:

Class A

VDE:

Class B

8. Reliability

MCBF:

3.5 million lines (equivalent to 0.5 million l-inch

labels at Font A)

9. Environmental conditions

Temperature

Humidity

Operating:

5 to 40°C

Storage:

-10 to 50°C (except for paper)

Operating:

30 to 85% (non-condensing)

Storage:

30 to 90%

(non-condensing, except for paper)

10. External dimensions and weight

Height:

124 mm

Width:

123 mm

Depth:

201 mm

Weight:

Approx. 0.8 kg

11. Case color

EPSON standard gray