Esc t n, Esc u, Range – Seiko Group TM-L60 User Manual

Page 46

Advertising
background image

[Description]

The pulse defined by nl and n2 is output on connector pin m.

l

m is specified as follows:

m

Connector pin

0 Drawer kick-out connector pin 2

1

Drawer kick-out connector pin 5

l

ON time is nl X 2 ms and OFF time is n2 X 2 ms.

l

The circuit on the user side should be designed so that the

drawer drive duty is as shown below.

ON time

(ON time + OFF time)

[Notes]

[Default]

It is recommended that n2 be four times as much as nl or more.

l

If m is out of range, the printer reads n1 and n2 but does not

output a pulse.

Neither m, n1, nor n2 is defined.

ESC t n

[Name]

Select character code table

[Format]

<1B>H<74>H<n>

[Range]

[Description]

Selects page n from the character code table.

[Default]

n = 0

[Reference]

APPENDIX D Character Code Tables

ESC u

n

[Name]

Transmit printer status

[Format]

<1B>H<75>H<n>

[Range]

n = 0

[Description]

Transmit the current status of connector pin.

l

n is specified as follows:

n

Connector pin

0

Drawer kick-out connector pin 3

40

Advertising