[Notes]

l

The syntax to be used when setting data in the print buffer
should be based upon GS CO.

l

For count mode, see GS Cl or GS C;.

With counting up

l

If the counter value set by this command goes out of the counter

operation range set by GS Cl or GS C;, it will be forced to
convert to the minimum by GS c.

With counting down

l

If the counter value set by this command goes out of the counter

operation range set by GS C1 or GS C;, it will be forced to
convert to the maximum by GS c.

GS f n

[Name]

Select font for HRI characters.

[Format]

<1D>H<66>H<n>

[Range]

n = 0, 1

[Description]

Selects a font for the HRI characters used when printing a bar

code.

l

n selects the font from the following table.

n

F o n t

0

Font A

1

F o n t B

l

HRI means Human Readable Interpretation.

[Notes]

l

HRI characters are printed at the position specified by GS H.

[Default]

n = 0

[Reference]

GSH

GS h n

[Name]

Select height of bar code

[Format]

<1D>H<68>H<n>

[Range]

1

≤ n

255

[Description]

Selects the height of the bar code.

l

n specifies the number of dots in the vertical direction.

[Default]

n= 162