Esc d [n]knul, Range – Seiko Group TM-L60 User Manual

Page 39

Advertising
background image

l

Each bit of n is used as follows:

Value

B i t

D e v i c e

0

1

0

Printer

Invalid

V a l i d

1

Undefined

2

Undefined

3

Undefined

4

Undefined

5

Undefined

6

U n d e f i n e d

7

Undefined

[Notes]

[Default]

l

Even when the printer is not selected, it may enter the BUSY

state due to printer operation.

n = 1

ESC @

[Name]

Initialize printer

[Format]

<1B>H<40>H

[Description]

Clears the data in the print buffer and resets the printer mode (to

the same state as when the power is turned on).

[Note]

l

The DIP switches are not read again.

l

The data in the receive buffer is not cleared.

l

Adjustment amount of the label starting position using < GS A >

command is not cleared.

ESC D [n]kNUL

[Name]

Set horizontal tab positions

[Format]

<1B>H<44>H[<n>]k<00>H

[Range]

1 n 255

0 k 32

[Description]

Sets horizontal tab positions.

l

"n” specifies the column number from beginning of the line for
setting a horizontal tab position.
[n= (Column number) - 1]. For example, when a tab is to be set
at column 9, n = 8.

l

"k" indicates the total number of horizontal tab positions to be

Set.

33

Advertising