2. Interface connector terminal assignments and signal functions

Pin Number Signal Name Signal Direction

Function

I

1

FG

-

Frame ground

2

TXD

output

Transmit data

3

RXD

Input

Receive data

6

DSR

Input

Data set ready

7

GND

-

Signal GND

20

DTR

output

Data terminal ready

3. Serial interface timing

a) Receive data

Either DTR/DSR or XON/XOFF control is selectable. Changes in DTR signal

and XON/XOFF transmission are as follows:

[DTR MARK]

l

The period from when the power is turned on to when

the printer first becomes ready to receive data.

l

In an error state.

l

When the remaining space in the receive buffer be

comes 10 bytes.

l

When feeding paper with the paper feed switch.

l

In paper feed switch waiting state with <GS FF>

command.

l

In paper feed switch waiting state during macro ex-

ecution.

l

When printing down-loaded bit image with <GS />.

[DTR SPACE]

l

When the printer first becomes ready to receive data

after power-on.

l

When the remaining space in the receive buffer be

comes 20 bytes.

[XON Transmission]

l

When DTR becomes SPACE.

[XOFF Transmission]

l

When DTR becomes MARK.

b) Transmit data (Status information transmission)

When DTR/DSR control is selected, data is transmitted after confirming that

DSR is SPACE. When DTR/DSR control is not selected, data is transmitted
regardless of the DSR state.

68