Range – Seiko Group TM-L60 User Manual

Page 55

Advertising
background image

[Default]

n1 + n2 x 256 = 1

[Reference]

GS CO, GS Cl, GS c, GS C;

GSC; N1; N2; N3; N4; N5;

[Name]

Select count mode (B)

[Format]

<1D>H<43>H<3B>H<N1><3B>H<N2><3B>H<N3><3B>H
<N4><3B>H<N5><3B>H

[Range]

0

N1

65535

0

N2

65535

0

N3

255

0

N4

255

0

N5

65535

[Description]

Select count mode of the serial number counter and specifies the
starting value of the counter.

W i t h c o u n t i n g u p

l

Counts up if N1<N2, N3

0, and N4

0.

l

N1 means the minimum value of the counter, and N2 the

maximum value.

W i t h c o u n t i n g d o w n

l

Counts down if N1>N2, N3 # 0, and N4

0.

l

N1 means the maximum value of the counter, and N2 the

minimum value.

To stop counting

l

Stops counting when N1 = N2, N3 = 0, or N4 = 0.

l

N3 indicates stepping amount while counting up or down.

l

N4 indicates repetition number with the counter value fixed.

l

N5 indicates the counter value.

l

When this command is issued, the inner counter that counts the

repetition number with counter value fixed will be cleared.

l

N7 to N5 can be omitted. If omitted, those parameter values will

be kept unchanged.

l

N7 to N5 cannot contain characters except O-9.

l

If incorrect syntax is used, the corresponding parameter setting

will have no effect and the data after that will be processed as

normal data.

W i t h c o u n t i n g u p

l

If the counting up reaches a value exceeding the maximum, it

will be resumed with the minimum.

[Notes]

4 9