Troubleshooting & repair – Lincoln Electric COMMANDER SVM153-A User Manual
Page 105
Advertising
TROUBLESHOOTING & REPAIR
F-52
F-52
COMMANDER 500
This is the typical auxiliary output
voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
Note: Scope probes connected at
machine 115VAC receptacle.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)
HIGH IDLE – NO LOAD
15.8 ms
0 volts
50V
5ms