TROUBLESHOOTING & REPAIR

F-54

F-54

COMMANDER 500

This is the typical DC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents
0.1 milliseconds in time.

The machine was loaded with a
resistance grid bank to 500 amps at
40 volts.

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep ..0.1 ms/Div.
Coupling.............................DC
Trigger.........................Internal

NORMAL WELD VOLTAGE WAVEFORM (STICK CC)

MACHINE LOADED TO 500 AMPS AT 40 VOLTS

0 volts

20V

0.1ms

Advertising