TROUBLESHOOTING & REPAIR

F-32

F-32

COMMANDER 500

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

PLUG P/J52

LEAD # 200A

LEAD # 201A

PLUG P/J52

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

FILTER
CAPACITOR

FIELD DIODE
RECTIFIER BRIDGE

FIGURE F.11 – PLUG P/J52 LOCATION

FLASHING AND ROTOR VOLTAGE TEST(CONTINUED)

TEST PROCEDURE

1. Using the 3/8" wrench, remove the sheet

metal screws from the right front case side.

2. Carefully remove the right case side.

3. Set the volt/ohmmeter to the DC volts

position.

4. Locate Plug P/J52 and leads #200A and

#201A. See Figure F.11.

NOTE: Cut any cable ties necessary to perform
the test. DO NOT UNPLUG PLUG P/J52.

5. Connect the positive meter probe to lead

#200A and the negative meter probe to lead
#201A.

6. Start the engine and run it at high idle speed

(1900 RPM). Check the voltage reading on
the meter. It should read approximately
16 VDC.