TROUBLESHOOTING & REPAIR

F-38

F-38

COMMANDER 500

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

WELD WINDING
LEAD CONNECTIONS

W6
W2
W4

W1
W3
W5

FIGURE F.16 – OUTPUT RECTIFIER DIODE BRIDGE

STATOR VOLTAGE TEST (CONTINUED)

4. Locate the weld winding leads connected to

the three-phase output rectifier diode bridge.
See Figure F.16.

5. Check for approximately 68VAC from W1 to

W2. Also check from W3 to W4 and from
W5 to W6.

6. If any of these voltages are low or missing

perform the Flashing and Rotor Voltage
Test
and also the Rotor Resistance Test.

7. Also check leads #6F and #5P for loose or

faulty connections to the field bridge. See
the Wiring Diagram.

8. If the tests in Steps 6 and 7 are OK and the

stator voltages are low or missing, the stator
may be faulty.

9. Replace the lower front panel and output

leads.

10. Replace the upper control panel and

secure.

11. Replace the front left and right case sides.