C-7

C-7

ACCESSORIES

COMMANDER 500

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CONNECTION OF THE LN-8 TO THE
COMMANDER 500 USING K595 INPUT
CABLE ASSEMBLY (SEE FIGURE C.4.)

1.

Shut the welder off.

2.

Connect the electrode cable from the LN-8 to the
“+” terminal of the welder. Connect the work
cable to the “-” terminal of the welder.

NOTE: Welding cable must be sized for current and
duty cycle of application.

NOTE: Figure C.4 shows the electrode connected for
positive polarity. To change polarity, shut the welder
off and reverse the electrode and work cables at the
Commander 500 output terminals.

3.

Connect the K595-XX Input Cable Assembly to the
LN-8.

4.

Connect the K595-XX to the 14-pin amphenol on
the Commander 500.

5.

Place the IDLER switch in the HIGH position.

Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory—do not adjust above RPM
specifications listed in this manual.

6.

Set the VOLTMETER switch to “+” or “-” depend-
ing on the polarity chosen.

7.

Set the OUTPUT RANGE switch to WIRE WELD-
ING CV.

8.

Set the WELDING TERMINALS switch to WELD-
ING TERMINALS REMOTELY CONTROLLED.

9.

Adjust wire feed speed and voltage at the LN-8.

10.

Adjust the ARC CONTROL to the desired level
(“soft” or “crisp”).

FIGURE C.4

COMMANDER 500/LN-8 WITH K595 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM

TO LN-8 INPUT
CABLE PLUG

AMPHENOL

ELECTRODE CABLE

TO WORK

14 PIN

K595 INPUT CABLE ASSEMBLY

TO WIRE FEED UNIT

+

CAUTION