PULL-IN COIL
(LARGER TERMINALS
EACH SIDE
#232M AND #265)

HOLD-IN COIL
(SMALLER TERMINALS
EACH SIDE
#224 AND #262)

SHUTDOWN
SOLENOID

IDLER
SOLENOID

FIGURE F. 25 – SHUTDOWN SOLENOID LEAD CONNECTIONS

SHUTDOWN SOLENOID REMOVAL AND REPLACEMENT (CONTINUED)

PROCEDURE

1. Turn engine off.

2. Unlatch, lift and secure the engine access

door.

3. Locate and remove the four spade connec-

tors that attach the shutdown solenoid termi-
nals to the wiring harness leads (#224,
#232M, #265 and #262). See Figure F.25.
Cut the cable tie.