TROUBLESHOOTING & REPAIR

F-33

F-33

COMMANDER 500

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FILTER
CAPACITOR

FIELD
DIODE
RECTIFIER
BRIDGE

FIGURE F.12 - FIELD DIODE RECTIFIER BRIDGE AND FILTER CAPACITOR

FLASHING AND ROTOR VOLTAGE TEST(CONTINUED)

7. If the voltage reading is low or not present,

the generator field is not functioning proper-
ly. Perform the Rotor Resistance Test.
Also check the field diode rectifier bridge, fil-
ter capacitor, and associated leads and con-
nections. See Figure F.12 for location. See
the Wiring Diagram.

NOTE: The normal flashing voltage is approxi-
mately 9VDC. This is battery voltage, which is
processed through the Battery board. This volt-
age must be present during start-up to "flash"
the rotor field.

8. If the rotor voltage readings are normal, the

field circuit is functioning properly. Replace
any cable ties cut during the test. Install the
right case side.