Accessories, Caution – Lincoln Electric COMMANDER SVM153-A User Manual

Page 35

Advertising
background image

C-9

C-9

ACCESSORIES

COMMANDER 500

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CONNECTION OF THE LN-25 TO THE
COMMANDER 500 “ACROSS THE ARC”
(SEE FIGURE C.6.)

1.

Shut the welder off.

2.

Connect the electrode cable from the LN-25 to the
“-” terminal of the welder. Connect the work cable
to the “+” terminal of the welder.

NOTE: Welding cable must be sized for current and
duty cycle of application.

NOTE: Figure C.6 shows the electrode connected for
negative polarity. To change polarity, shut the welder
off and reverse the electrode and work cables at the
Commander 500 output terminals. Reverse the LN-25
polarity switch.

3.

Attach the single lead from the LN-25 to the work
using the spring clip on the end of the lead. This is
only a sense lead – it carries no welding current.

4.

Place the IDLER switch in the AUTO position.

If you are using an LN-25 without an internal contactor,
the electrode will be HOT when the Commander 300 is
started.

5.

Set the OUTPUT RANGE switch to WIRE WELD-
ING CV.

6.

Set the WELDING TERMINALS switch to WELD-
ING TERMINALS ALWAYS ON.

7.

Set the VOLTMETER switch to “+” or “-” depend-
ing on the polarity chosen.

8.

Adjust wire feed speed at the LN-25.

9.

Adjust the ARC CONTROL to the desired level
(“soft” or “crisp”).

FIGURE C.6

COMMANDER 500/LN-25 ACROSS THE ARC CONNECTION DIAGRAM

AMPHENOL

TO WORK

WORK CLIP LEAD

LN-25

WIRE FEEDER

OPTIONAL K444-1

REMOTE CONTROL

AMPHENOL

6 PIN

14 PIN

TO WORK

ELECTRODE CABLE

CAUTION