TROUBLESHOOTING & REPAIR

F-55

F-55

COMMANDER 500

NORMAL WELD VOLTAGE WAVEFORM (WIRE CV)

MACHINE LOADED TO 500 AMPS AT 40 VOLTS

This is the typical DC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents 5
milliseconds in time.

The machine was loaded with a
resistance grid bank to 500 amps at
40 volts.

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep ..0.1 ms/Div.
Coupling.............................DC
Trigger.........................Internal

0 volts

20V

0.1ms