TABLE D.1

DEUTZ ENGINE MAINTENANCE SCHEDULE

FREQUENCY

MAINTENANCE REQUIRED

Daily or Before
Starting Engine

• Fill fuel tank.
• Check oil level.
• Check air cleaner for dirty, loose, or damaged parts. Replace if necessary.
• Check air intake and cooling areas, clean as necessary.

1

First 50 Hours

• Change engine oil.

and Every 250

• Change oil filter.

Hours Thereafter • Change fuel filter.

• Check fan belt.

Every 50 Hours

• Check fuel lines and clamps.

Every 100 Hours

• Check battery electrolyte level and connections.
• Clean air filter.

Refer to your Deutz engine operation manual for periodic maintenance at 100 hours and beyond.

1

125 Hours for severe conditions.

TABLE D.2

ENGINE MAINTENANCE PARTS

ITEM

Air Cleaner Element

Cooling Blower Belt

Oil Filter Element

Fuel Filter Element

Water Separator Element

Fuel Pre-Filter Screen

Battery

MANUFACTURER

Donaldson

AC

Lincoln

Gates

Deutz

Purolator

Napa

Fram

Deutz

Purolator

Napa

Fram

Lincoln

Stanadyne

Lincoln

Stanadyne

PART NUMBER

P181052

A302C

T13536-3

7585

1174418

PER2168

1820

PH3776

1174423

PC42

3358

P4102

M16890-C

31572

M16890-B

29575

BCI

Group

34