background image

TROUBLESHOOTING & REPAIR

F-44

F-44

COMMANDER 500

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

GREEN
GROUND
LEAD

OUTPUT PANEL

SCREWS

OUTPUT LEADS
(BEHIND PANEL)

FIGURE F.19 – OUTPUT PANEL REMOVAL

OUTPUT RECTIFIER BRIDGE TEST(CONTINUED)

7. Using the 3/8" wrench, remove the three

screws holding the lower front panel (output
panel) to the case front assembly. Then
remove the front two screws holding the top
of the panel. These are accessed in the
control box, on the bottom at each side of
the box. Using the 7/16" wrench, discon-
nect the green ground lead. See Figure
F.19. Carefully move the lower front panel
to the right side.

8. Disconnect Bypass PC board leads #206B

and #208 from their in-line connectors.