TROUBLESHOOTING & REPAIR
F-41
F-41
COMMANDER 500
TABLE F.1
ANALOG CONTROL POWER SUPPLY PC BOARD VOLTAGE TABLE
Test Points
Component Tested
Voltage Reading
1J42 to 6J42
Chopper Power Supply
+20 VDC
3J42 to 8J42
Chopper Power Supply
+20 VDC
2J42 to 7J42
Weld Control PC Board Power Supply
+5 VDC
5J42 to 7J42
Weld Control PC Board Power Supply
+15 VDC
9J42 to 7J42
Weld Control PC Board Power Supply
-15 VDC
10J42 to 4J42
Weld Control PC Board Power Supply
+15 VDC
ANALOG CONTROL POWER SUPPLY PC BOARD TEST (CONTINUED)