Troubleshooting & repair, Normal open circuit voltage waveform (stick) – Lincoln Electric COMMANDER SVM153-A User Manual

Page 106

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-53

F-53

COMMANDER 500

This is the typical DC open circuit out-
put voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.

SCOPE SETTINGS

Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (STICK)

MAX TAP – MAX CONTROL POT – HIGH IDLE – NO LOAD

0 volts

50V

5ms

Advertising