TROUBLESHOOTING & REPAIR

F-42

F-42

PIPELINER® 200

This is the typical DC welding output

voltage generated from a properly

operating machine. Note that each

vertical division represents 50 volts

and that each horizontal division

represents 5 milliseconds in time.

Note: Scope probes connected at

machine output terminals.

SCOPE SETTINGS

Volts/Div.....................50V/Div.

Horizontal Sweep.....5 ms/Div.

Coupling.............................DC

Trigger.........................Internal

NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AND SELECTOR

SWITCH AT MAXIMUM

0 volts

5 ms

50 volts