OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

The engine will not return to low

idle when the welding and

auxiliary loads are removed.

1. Make sure the idler control

switch is set to the “Auto”

position.

2. Make sure both welding and

auxiliary loads are removed.

3. Check for mechanical

restrictions in the idler and

throttle linkage (PERKINS

code 10929 ONLY) There may

be a problem with the ECU or

Throttle Body Controller or

associated engine control

components on Kubota Diesel

(1114, 11316) and GM

Gas(10660, 10913,

11136)Contact the Lincoln

Electric Service Dept. 1-888-

935-3877.

1. Check the idler control switch

and associated leads for

loose or faulty connections.

See the Wiring Diagram.

2. Check the CURRENT

SENSING PC BOARD

Perform the Current Sense

Board Test. Replace if

necessary.

3. Perform the Idler Solenoid

Test. (PERKINS 10929

ONLY)

4. Check for loose or faulty

connections at the idler PC

board (PERKINS) ECU in

Kubota and Throttle Body

Controller GM 3.0 liter.

5. The idler PC board

(PERKINS) ECU in Kubota or

Throttle Body Controller -GM

3.0 liter may be faulty.

Contact the Lincoln Electric

Service Dept. 1-888-935-

3877.

TROUBLESHOOTING & REPAIR

F-7

F-7

PIPELINER® 200

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Advertising