OPERATION

BBB-4

BBB-4

PIPELINER® 200G

CONTROL OF WELDING CURRENT

DO NOT TURN THE “CURRENT RANGE SELEC-

TOR” WHILE WELDING because the current may

arc between the contacts and damage the switch.

------------------------------------------------------------------------

The “Current Range Selector” provides five overlap-

ping current ranges. The “Fine Current Adjustment”

adjusts the current from minimum to maximum within

each range. Open circuit voltage is also controlled by

the “Fine Current Adjustment” permitting control of the

arc characteristics.

A high open circuit voltage setting provides the soft

“buttering” arc with the best resistance to pop-outs pre-

ferred for most welding. To get this characteristic, set

the “Current Range Selector” to the lowest setting that

still provides the current you need and set the “Fine

Current Adjustment” near maximum. For example: to obtain

175 amps and a soft arc, set the “Current Range Selector” to

the 190-120 position and then adjust the “Fine Current

Adjustment” for 175 amps.

When a forceful “digging” arc is required, usually for

vertical and overhead welding, use a higher “Current

Range Selector” setting and lower open circuit voltage.

For example: to obtain 175 amps and a forceful arc, set

the “Current Range Selector” to the 240-160 position

and the “Fine Current Adjustment” setting to get 175

amps.

DO NOT attempt to set the “Current Range Selector”

between the five points designated on the nameplate.

------------------------------------------------------------------------

These switches have a spring loaded cam which

almost eliminates the possibility of setting this switch

between the designated points.

TBI DEICING SYSTEM

The welder has been designed to allow continuous

year-round operation. Engine coolant is channeled

through the TBI housing to prevent the build up of ice

on the TBI throat around the throttle plate. the elec-

tronic controller is programmed to automatically com-

pensate for the build up of ice on the throttle plate.

There will be no noticeable change in the operation of

the welder should icing develop. On start-up, there is a

possibility for the engine to overspeed (to a maximum

of 2000 RPM) for up to 10 seconds after throttle body

icing conditions have occurred. The electronic gover-

nor will correct itself for the new operating conditions

and normal operation will resume.

IDLER OPERATION

The operating speeds are as follows:

The idler is controlled by the “Idler” toggle switch on the

welder control panel. The switch has two positions as

follows:

1. In the “High”

position, the idler is off, and the

engine runs at the high speed controlled by the gov-

ernor. This speed can be adjusted between 1500

and 1600 RPM using the RPM dial on the output

rail.

2. In the “Automatic”

/

position, the

idler operates as follows:

• When welding or drawing power for lights or tools

(approximately 100-150 watts minimum) from the

receptacle, the engine operates at the speed, set

by the RPM dial.

• When welding ceases or the power load is turned

off, a preset time delay of 10 seconds starts. This

time delay cannot be adjusted.

• If the welding or power load is not re-started

before the end of the time delay, the idler reduces

the engine to low idle speed.

AUXILIARY POWER

1.75 kw of 120V DC auxiliary power is available at the

receptacle located on the control panel.

CAUTION

CAUTION

ORDERING

INFO.

ENGINE

FULL

LOAD

HIGH

IDLE

LOW

IDLE

K6090-7 GM 3.0L

1600-

1500

1600-

1500

1360

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Advertising