Theory of operation, E-6 pipeliner® 200 – Lincoln Electric PIPELINER 200 User Manual

Page 68

Advertising
background image

THEORY OF OPERATION

E-6

E-6

PIPELINER® 200

ENGINE, MAIN GENERATOR ARMATURE

& FRAME AND DC EXCITER

EXCITATION (FLASHING)

The main generator armature and the exciter armature

are mechanically coupled to the engine. When the

engine is started and running, the residual magnetism

that is stored in the exciter pole pieces is induced upon

the exciter armature. This causes the exciter to “build-

up” and produce a DC output voltage. This DC is

applied, via the field rheostat control, to the main gen-

erator shunt field coils. The exciter output is also con-

nected to the 120VDC receptacle.

MAIN SHUNT, INTERPOLE & SERIES COILS

The generator armature rotates within the magnetic

field created by the shunt field windings. A DC voltage

is induced in the armature and is transferred, through

the armature commutator and brushes, to the series

and interpole coils. The interpole coils, which are con-

nected in series with the positive output terminal, are

located so as to counteract any magnetic influences

that could cause mechanical distortion in the rotating

armature. The series coils are designed to oppose or

“buck” the DC voltage that is generated in the arma-

ture.

ENGINE, MAIN GENERATOR ARMATURE, FRAME

& DC EXCITER

CURRENT RANGE SELECTOR

The selector switch acts as a course current adjust-

ment by allowing varying amounts of series windings to

be included in the welding current path. The series

coils and selector switch are connected in series with

the negative output terminal.

FINE CURRENT ADJUSTMENT

The field rheostat control functions as a fine output cur-

rent adjustment by controlling the current through the

shunt windings, thus controlling the amount of magnet-

ism created in the field windings. Open circuit weld

voltage can also be controlled by the field rheostat con-

trol.

FIGURE E.6 — GENERATOR & EXCITER

NEGATIVE
OUTPUT
TERMINAL

SWITCH

-

SELECTOR

90 Min.

Max

GENERATOR

ARMATURE

B

R

U

S

H

E

S

&

C

O

M

M

U

T

A

T

O

R

INTERPOLE

COILS

RESIDUAL

MAGNETISM

GENERATOR

FIELD CONTROL

SHUNT

FIELD

SERIES

FIELD

ARMATURE

EXCITER

DC

ARMATURE

SHAFT

_

+

SERIES

COILS

TO

ENGINE

CONTROL/PROTECTION

MODULE

POSITIVE
OUTPUT
TERMINAL

+

SHUNT
FIELD
COILS

15 AMP

FUSE

RECEPTACLE
120VDC

MECHANICAL

COUPLING

+

-

Current
Sensing
P.C. Board

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC