The engine “cranks” but will not start, Troubleshooting & repair, Caution – Lincoln Electric PIPELINER 200 User Manual

Page 79

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

The engine will NOT go to high

speed when a load is applied to

the DC auxiliary receptacle. The

engine does go to high speed

when a load is applied to the

welding output terminals. When

the engine is operating in the

high RPM condition, both

welding output and DC auxiliary

are normal.

1. Check the auxiliary power plug

and associated leads for loose

or faulty connections.

2. The load may be too small.

The load must be above 150

watts.

The engine “cranks” but will not

start.

1. Make sure the ignition switch

is in the ON position.

2. Check for adequate fuel

supply.

1. Check the ignition switch for

proper operation. Check the

associated leads for loose or

faulty connections. See the

Wiring Diagram.

2. Check the fuel solenoid. Make

sure it is opening when

+12VDC is applied.(Except

Kubota) See the Wiring

Diagram.

3. The idler PC board may be

faulty (Perkins 10929)

Replace, OR The ECU Kubota

or Throttle Body Controller GM

3.0 Liter may be faulty. Contact

the Lincoln Electric Service

Dept. 1-888-935-3877.

TROUBLESHOOTING & REPAIR

F-9

F-9

PIPELINER® 200

1. Check the idler control switch

and associated leads for

loose or faulty connections.

See the Wiring Diagram.

2. Check the CURRENT

SENSING PC BOARD.

Perform the Current Sense

Board Test. Replace if

necessary.

3. Perform the Idler Solenoid

Test. (PERKINS 10929

ONLY)

4. Check for loose or faulty

connections at the idler PC

board (PERKINS) ECU in

Kubota and Throttle Body

Controller GM 3.0 liter.

5. The idler PC board

(PERKINS) ECU in Kubota or

Throttle Body Controller -GM

3.0 liter may be faulty.

Contact the Lincoln Electric

Service Dept. 1-888-935-

3877.