OPERATION

BB-3

BB-3

PIPELINER® 200D PERKINS

Cranking System

A 12V electric starter is standard.

Air Cleaner

Heavy duty two-stage dry type

Exhaust

A muffler and stainless steel exhaust outlet pipe are

standard.

Engine Hour Meter

A meter to record the hours of operation.

ENGINE OPERATION

Operate the welder with the doors closed. Leaving the

doors open changes the designed air flow and can

cause overheating.

STARTING THE PIPELINER® 200D PERKINS

104.22 DIESEL ENGINE

1. Turn the “IDLER” switch to “HIGH”.

2. Turn the “IGNITION” switch to “ON”.

3. Press the Glow Plug button for 20 to 30 seconds.

(maximum 60 seconds).

4. Press the Start button. When the engine starts run-

ning, release both buttons. If the engine fails to start

in 20 seconds, wait 30 seconds and repeat the

above procedure.

5. Observe the oil pressure. If no pressure shows with-

in 30 seconds, stop the engine and consult the

engine operating manual. To stop the engine, turn

the “IGNITION” switch to “OFF”.

6. If the engine protection warning light comes on dur-

ing cranking or after start up, the “IGNITION” switch

must be turned “OFF” to reset the engine protection

system.

7. Allow the engine to run at high idle speed for sever-

al minutes to warm the engine. Stop the engine and

recheck the oil level after allowing sufficient time for

the oil drain into the pan. If the level is down, fill it to

the full mark again. The engine controls were prop-

erly set at the factory and should require no adjust-

ing when received.

COLD WEATHER STARTING

With a fully charged battery and a proper weight oil, the

engine should start satisfactorily even down to about -

15°F -(26°C). If the engine must be frequently started

at or below -15°F -(26°C), it may be desirable to install

cold-starting aides.

Note: Extreme cold weather starting may require

longer glow plug operation

Under NO conditions should ether or other starting

fluids be used!

------------------------------------------------------------------------

STOPPING the ENGINE

1. Turn the “IGNITION” switch to “OFF”

At the end of each dayʼs welding, check the crankcase

oil level, drain accumulated dirt and water from the

sediment bowl under the fuel tank and refill the fuel

tank to minimize moisture condensation in the tank.

Also, running out of fuel tends to draw dirt into the fuel

system.

When hauling the welder between job sites, close the

fuel feed valve beneath the fuel tank.

If the fuel supply is cut off or runs out while the fuel

pump is operating, air may be entrapped in the fuel dis-

tribution system. If this happens, bleeding of the fuel

system may be necessary. Use qualified personnel to

do this per the instructions in the MAINTENANCE sec-

tion of this manual.

WARNING

PIPELINER® 200D WITH PERKINS 104.22

DIESEL ENGINE

TYPICAL FUEL CONSUMPTION DATA

Low idle (1400 RPM )

.33gal/hr (1.25ltrs/hr )

No Load

High idle ( 1800 Rpm )

.39gal/hr (1.48ltrs/hr )

No load

200 Amps @ 28 Volts

.67gal/hr (2.54ltrs/hr )

200 Amps @ 40 Volts

.75gal/hr (2.84ltrs/hr )

Auxiliary Power

15 Amps @ 120 Volts

.50gal/hr (1.89ltrs/hr)

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Advertising