Troubleshooting & repair, Caution – Lincoln Electric PIPELINER 200 User Manual

Page 78

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

The engine will NOT go to high

speed when a load is applied to

the welding output terminals.

The engine does go to high

speed when a load is applied to

the DC auxiliary power

receptacle. When the engine is

operating in the high RPM

condition, both welding output

and DC auxiliary are normal.

1. Check welding cables for loose

or faulty connections.

TROUBLESHOOTING & REPAIR

F-8

F-8

PIPELINER® 200

1. Check the idler control switch

and associated leads for

loose or faulty connections.

See the Wiring Diagram.

2. Check the CURRENT

SENSING PC BOARD.

Perform the Current Sense

Board Test. Replace if

necessary.

3. Perform the Idler Solenoid

Test. (PERKINS 10929

ONLY)

4. Check for loose or faulty

connections at the idler PC

board (PERKINS) ECU in

Kubota and Throttle Body

Controller GM 3.0 liter.

5. The idler PC board

(PERKINS) ECU in Kubota or

Throttle Body Controller -GM

3.0 liter may be faulty.

Contact the Lincoln Electric

Service Dept. 1-888-935-

3877.