OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

The engine starts and runs at

correct speed, but there is no, or

very low, welder output voltage.

There is no DC auxiliary output

voltage.

1. Check for loose or missing

brushes in the DC exciter.

2. The exciter may need

“flashing.” See Flashing the

Fields in this section.

1. Check for loose or broken

wires between the exciter

brushes and the DC

receptacle and the fine

current control field rheostat.

See the Wiring Diagram.

2. Perform the DC Exciter Test.

The engine starts and runs at

the correct speed but there is no,

or very low, welder output. The

DC auxiliary output voltage is

normal.

1. Check the welding cables for

loose or faulty connections.

2. Check for loose or missing

brushes in the welding

generator.

3. Check for open circuit voltage

at weld studs, check heavy

current carrying leads for loose

or corroded connections

1. Check the fine current control

field rheostat for resistance

and proper operation. Normal

resistance is 64 ohms. Check

associated wires for loose or

faulty connections. See the

Wiring Diagram.

2. Perform the Main Generator

Shunt Field Winding Test.

3. Check the continuity of the

interpole coils. They should

show continuity from the

positive brusholders to the

positive output terminal and

should NOT be grounded to

the generator frame.

4. Check the continuity of the

series coils. They should

show continuity from the

negative brusholders, through

the current selector switch, to

the negative output terminal

and should NOT be grounded

to the generator frame.

5. The main armature may be

faulty. Check for grounds

and/or shorts.

TROUBLESHOOTING & REPAIR

F-4

F-4

PIPELINER® 200

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Advertising