MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE

(CONTINUED)

TROUBLESHOOTING & REPAIR

F-57

F-57

PIPELINER® 200

FIGURE F.24 – BRUSH BRACKET WRAP-AROUND COVER

BRUSH BRACKET

WRAP- AROUND COVER

REMOVE (2) NUTS,
WASHERS, AND SCREWS

27. Using the slot head screw driver, remove the

two screws and nuts from the brush bracket

wrap-around cover. Remove the cover. See

Figure F.24.

FIGURE F.25 – MAIN GENERATOR BRUSH BRACKET CLAMPING BOLT

BRUSHES (8)

CLAMPING BOLT

BRUSH BRACKET

28. Lift the eight brushes from the main commu-

tator. Note their positions for reassembly.

29. Using the 7/16” wrench, loosen (do not

remove) the main generator brush bracket

clamping bolt. Note the position of the drill

spot for reassembly. See Figure F.25.