MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE
(CONTINUED)
TROUBLESHOOTING & REPAIR
F-57
F-57
PIPELINER® 200
FIGURE F.24 – BRUSH BRACKET WRAP-AROUND COVER
BRUSH BRACKET
WRAP- AROUND COVER
REMOVE (2) NUTS,
WASHERS, AND SCREWS
27. Using the slot head screw driver, remove the
two screws and nuts from the brush bracket
wrap-around cover. Remove the cover. See
Figure F.24.
FIGURE F.25 – MAIN GENERATOR BRUSH BRACKET CLAMPING BOLT
BRUSHES (8)
CLAMPING BOLT
BRUSH BRACKET
28. Lift the eight brushes from the main commu-
tator. Note their positions for reassembly.
29. Using the 7/16” wrench, loosen (do not
remove) the main generator brush bracket
clamping bolt. Note the position of the drill
spot for reassembly. See Figure F.25.