Troubleshooting & repair – Lincoln Electric PIPELINER 200 User Manual

Page 126

Advertising
background image

MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE

(CONTINUED)

TROUBLESHOOTING & REPAIR

F-56

F-56

PIPELINER® 200

FIGURE F.23 – FRONT PANEL FASTENER REMOVAL

BOLTS / NUTS / WASHERS (2)

BASE MOUNTING BOLTS (4)

MIDDLE SCREW (1)

23. Using the 1/2” wrench, remove the two bolts,

nuts, and washers that hold the front panel

assembly to the horizontal rails. (There is

one on each side.) See Figure F.23.

24. Using the 9/16” wrench, remove the four

bolts, nuts, and washers from the bottom of

the front panel assembly. These four bolts

mount the front to the base. (There are two

on each side.) See Figure F.23.

25. Using the 3/8” nut driver, remove the screw

from the lower middle of the front panel. See

Figure F.23.

26. Carefully remove the front panel assembly.