Troubleshooting & repair – Lincoln Electric PIPELINER 200 User Manual
Page 128
Advertising
MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE
(CONTINUED)
TROUBLESHOOTING & REPAIR
F-58
F-58
PIPELINER® 200
FIGURE F.26 – MAIN GENERATOR FEET MOUNTING
MAIN GENERATOR
REMOVE MOUNTING
NUTS, WASHERS,
AND BOLTS
FEET (2)
30. Using the 3/4” wrench, remove the frame
mounting bolts, nuts, and washers from the
feet of the main generator. See Figure F.26.
FIGURE F.27 – MAIN GENERATOR ENGINE MOUNTING
ENGINE / GENERATOR
MOUNTING HOLES
SLING
31. With the rope sling around the main genera-
tor frame, carefully lift the frame a small dis-
tance. Slide the wood or steel blocks under
the engine. See Figure F.27.
32. Using the 9/16” wrench, remove the bolts
and lock washers mounting the generator
frame to the engine. See Figure F.27.
Advertising