MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE

(CONTINUED)

TROUBLESHOOTING & REPAIR

F-50

F-50

PIPELINER® 200

FIGURE F.16 – BATTERY PANEL REMOVAL

NEGATIVE
BATTERY
CABLE

PROCEDURE

1. Turn the engine OFF.
2. Using the 7/16” wrench, remove the two bolts

and washers and partially slide out the battery

mounting panel. See Figure F.16.

3. Using the 1/2” wrench, remove the negative

battery cable.