TROUBLESHOOTING & REPAIR

F-63

F-63

PIPELINER® 200

RETEST AFTER REPAIR

Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machineʼs electrical characteristics.

OR
• If you repair or replace any electrical components.

ENGINE OUTPUT

Engine

Mode

No Load RPM

Load RPM

Perkins

Low Idle

1375-1425

NA

Perkins

High Idle

1540-1650

1450-1600

Kubota

Low Idle

1390-1410

NA

Kubota

High Idle

1580-1600

1550-1600

GM (Gas)

Low Idle

1340-1360

NA

GM (Gas)

High Idle

1580-1600

1550-1600

WELDER DC OUTPUT

Current Control

Current Selector

Open Circuit

Load Volts

Load Amps

Rheostat

Switch

Voltage

Maximum

Maximum

88-98

33-39

300

DC AUXILIARY POWER RECEPTACLE OUTPUT

Open Circuit Voltage

Load Volts

Load Amps

124-138

115-130

15.0

FIELD AMPS AND VOLTS

(Current Rheostat at Maximum)

Exciter DC Volts

Main Shunt Field Amps

RPM

123 - 137

2.10-2.70

1540-1600

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC