Troubleshooting & repair, Scr removal and replacement (continued), Caution – Lincoln Electric PRECISION TIG 275 SVM162-B User Manual

Page 106: Cathode gate anode outer metal ring

Advertising
background image

F-60

F-60

PRECISION TIG 275

TROUBLESHOOTING & REPAIR

SCR REMOVAL AND REPLACEMENT (continued)

SPECIAL INSTRUCTIONS

NOTE: Before disassembling the existing recti-

fier, note toward which heat sink the outer

metal ring of the power SCR is mounted. Also,

note the positioning of the gate lead of the

SCR. Failure to reinstall the new SCR in the

same orientation as the original may result in

subsequent damage to the new SCR and

other components of the welder. See Figure

F.16.

The unclamping and clamping procedure out-

lined below is critical for the prevention of

internal SCR damage. Failure to follow this

procedure may result in subsequent damage

of the SCR. Handle all SCRs with care.

PROCEDURE

1. Remove the main input supply power to the

machine.

2. Perform the

SCR/Diode Rectifier

Assembly Removal

procedure.

3. Using a 7/16” open end wrench, alternately

loosen nuts 1/2 turn each until heat sinks

are loose. Remove nuts and leaf spring. IT

IS RECOMMENDED THAT NEW HARD-

WARE, LEAF SPRING AND HOUSING BE

USED FOR ASSEMBLY.

4. Remove the old SCR.

5. Clean the area on the heat sink around the

SCR mounting surface, using a putty knife

or similar tool. DO NOT SCRATCH THE

SCR MOUNTING SURFACE.

6. Polish each heat sinkʼs mounting surface

using NO.000 fine steal wool. Wipe surface

clean with a lint free cloth or paper towel.

7. Inspect the mounting surfaces of each new

SCR.

a. Remove all burrs and wipe clean. Do

not use steel wool or any abrasive

cleanser on the SCR mounting sur-

faces.

8. Apply a thin (0.001” to 0.003”) layer of

PENETROX A-13 (Lincoln Electric #E2529)

or PENTROX A, heat sink compound, to

each heat sinkʼs SCR mounting surface.

a. Care must be used to prevent foreign

material contamination of the SCR to

heat sink junction.

9. Place the new SCR between the heat

sinks. Be sure that the outer metal ring of

the SCR is facing toward the same heat

sink as the old SCRʼs metal ring. Be sure

that the roll pin of the heat sink engages

the “hole” in the SCR. The SCR contact

surfaces must sit flat against both heat sink

surfaces.

10. Perform the

SCR/Diode Rectifier

Assembly Replacement Procedure.

11. Replace the case sides and top.

Cathode

Gate

Anode

Outer Metal

Ring

Figure F.16 - SCR DETAILS