AUXILIARY POWER CONNECTIONS

The Precision TIG machines provide a standard NEMA

5-15R duplex receptacle, located on the upper case

back on the torch side of the machine:

• The bottom outlet of this duplex receptacle provides

switched 115VAC power for the Under-Cooler, or

Water Solenoid accessory. This Cooler receptacle

turns on when the arc starts and remains on for about

8 minutes after the arc goes out (with the Fan-As-

Needed machine cooling fan, see Maintenance

Section), so the Coolerʼs fan and water pump will not

run continuously in idle, but will run while welding.

• The top outlet of this duplex receptacle provides at

least 8 amps at 115VAC, whenever the Precision TIG

Power switch is ON. This auxiliary circuit is intended

for running 115VAC accessories or small power tools.

Note: Some types of equipment, especially pumps

and large motors, have starting currents which are

significantly higher than their running current. These

higher starting currents may cause the circuit breaker

to open. (See next paragraph)

• Both the receptacle circuits are protected from shorts

and overloads by a 15 amp circuit breaker, located

above the receptacle. if the breaker trips its button

pops out exposing a red ring. When the circuit break-

er cools the button can be reset by pressing it back

in.

Note: When the breaker trips not only will the auxil-

iary and cooler power be interrupted, but so will the

power to the shielding gas solenoid and machine

cooling fan.

The Precision TIG Export models also provide a

grounded 220 VAC Euro type Schuko receptacle and a

5 amp circuit breaker, located on the upper case back

on the reconnect side of the machine, intended for use

with a 220 VAC water cooler.

REMOTE CONTROL (If Used)

The Foot Amptrol (included with the Precision TIG

Welding Package), or other Remote accessory, is

installed by routing the plug of its control cable up

through the left cable strain relief hole provided in the

base (see Figure A.2), then connecting the 6-pin plug

to the mating Remote receptacle behind the stud panel

cover. (See Operation Section B-2 for mating plug

wiring.)

Note: If the Precision TIG is equipped with an Under-

Cooler or Under-Storage unit, the Foot Pedal (or other

remote control accessory) and coiled control cable, or

excess cable length, may be conveniently stored in the

drawer while remaining connected.

FIGURE A.3

For Gas Supply hose

with 5/8-18RH male

(Provided with Weld

Package model)

For Coolant Supply

Hoses

with 5/8-18LH male

(Provided with Weld

Package model

or

Under-Cooler Cart)

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising