Operation, Caution, Advanced panel controls – Lincoln Electric PRECISION TIG 275 SVM162-B User Manual

Page 23

Advertising
background image

B-7

OPERATION

B-7

8. DIGITAL METER AND DISPLAY SWITCH

– A 3-

digit LED meter is used to monitor the preset and

actual welding procedure based on the Display

(momentary) switch position:

• Before welding with Display switch in center (nor-

mal) position, the digital meter displays the preset

welding amps set by Maximum Output control knob

(See Item 6). If in Stick mode using REMOTE (See

Item 5.), the digital meter displays the preset weld-

ing amps set by the Remote control. (See Item 11)

• While welding with Display switch in center (normal)

position, the digital meter displays the actual weld-

ing amps with one amp resolution (XXX) and accu-

racy within 4%+/-2A of reading.

• At any time in TIG mode, pressing the Display

switch to left causes the digital meter displays the

amps preset by the Minimum Output control knob

(See Item 7).

• At any time in Stick mode, pressing the Display

switch to left causes the digital meter to display the

minimum amps rating of the machine (See Item 7).

• In either mode, while pressing the Display switch

right to Volts position, the digital meter displays

actual output volts. Volts is displayed with 0.1 volt

resolution (XX.X) and accuracy within 3%+/-1V of

reading.

9. POSTFLOW TIME

– This knob is used to set the

TIG mode shielding gas postflow time over the

range of about 2 to 60 seconds after the arc is shut

off. The postflow on time status is indicated by the

Green panel light.

• Gas preflow time for TIG mode is fixed at 0.5 sec-

onds, with no panel control.

• Both time ranges are x2 extendable, if needed, by

internal control box selection. (See Section B-7)

10. THERMAL SHUTDOWN LIGHT

– This yellow LED

panel light turns on if the machine output is shut-

down because internal overheating has occurred,

and turns off when the thermostat resets.

11. REMOTE RECEPTACLE

– A 6-socket receptacle

is provided for the connection of an Amptrol, or

other remote control: (See Figure B.2)

• When the Current Control Switch (See Item 5) is in

the REMOTE position, the Amptrol or other remote

(10K pot) connected to the Remote receptacle con-

trols the TIG or Stick mode output within the range

preset by the Maximum and Minimum Output con-

trols. (See Item 6, 7, and 8 for meter display.)

• When the Current Control Switch is in either LOCAL

or REMOTE positions the arc start switch functions

when connected to the Remote receptacle.

ADVANCED PANEL CONTROLS

The following controls are included only if the Precision

TIG 275 has the Advanced Control Panel (K1829-1)

option installed: (Refer to

Figure B.3

Tig Weld Cycle

Chart for graphic illustration of these TIG welding func-

tions.)

12. TRIGGER SWITCH

– This 2-position switch

selects how the arc start switch ( connected to the

above Remote receptacle) functions; in 2-Step or

4-Step mode:

• DO NOT USE 4-STEP IF USING AN AMPTROL

REMOTE.

• Neither the arc start switch nor the output con-

trol in the amptrol will function normally to shut

off or control the output. ONLY USE 2-STEP.

------------------------------------------------------------------------

• In 2-Step position the arc start switch functions the

same as without the Advanced Panel:

1. Closing switch starts preflow, then a fixed

(0.5 sec.) ramp time from Minimum (Start)

setting level (See Item 7) to Weld setting.

2. Opening switch initiates Downslope ramp

time setting (See Item 17), from Weld set-

ting to Crater-fill level (See Item 7), which

then stops the arc and initiates Postflow

time (See Item 9).

Note: See

Figure B.3

for 2-Step operation during

Downslope with Restart feature selected to be dis-

abled, instead of enabled (as shipped).

PRECISION TIG 275

A

B

C

D

E

F

Max

10K ohm

Min

REMOTE RECEPTACLE*

(Front View)

REMOTE OUTPUT

CONTROL

ARC START

SWITCH

*For 18-12P Plug

(LECO S12020-27)

CAUTION

FIGURE B.2

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising