TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-

tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

FUNCTION PROBLEMS

The meter does not display V (volt)

or minimum current.

NOTE: BEFORE REPLACING A

CONTROL BOARD

If an Advanced Control Panel is

installed, remove it and replace

the Jumper in connector J-3. If

the machine functions normally,

the Advanced Process panel or

harness is defective.

1. Toggle the display switch. It may

be dirty.

1. Check the leads between the

display switch and the control

board. See the Wiring Diagram.

2. The display switch may be faulty.
3. The control board may be faulty.

The meter does not light up. Other

machine functions are OK.

NOTE: BEFORE REPLACING A

CONTROL BOARD

If an Advanced Control Panel is

installed, remove it and replace

the Jumper in connector J-3. If

the machine functions normally,

the Advanced Process panel or

harness is defective.

1. None

1. Check the leads and connec-

tions between the meter and the

control board. See the Wiring

Diagram.

2. The meter may be faulty.
3. The control board may be faulty.

CAUTION