TECHNICAL SPECIFICATIONS-PRECISION TIG 275 (Domestic, Canadian & Export

Voltage + 10%

208/230/460

460/575

220-230/

380-400/415

Max. Amps With Out

Power Factor Capacitor

104/94/47

124/112/56

86/78/39

95/86/43

77/70/35

73/66/33

6/5/3

47/38

56/45

39/31

43/35

35/28

33/26

3/2

300W

95/55/50

109/63/58

80/46/42

85/49/45

70/41/37

65/38/35

10/6/5

400W

Max. Amps With

Power Factor Capacitor

80/72/36

95/86/43

64/58/29

62/56/28

55/50/25

40/36/18

36/32/16

35/28

43/34

29/23

28/23

25/20

18/14

16/13

500W

80/46/43

86/50/46

64/37/34

67/39/36

52/30/28

46/27/25

23/13/12

500W

Duty Cycle-Applications

40%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

60%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

100%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

Idle Amps

40%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

60%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

100%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

Idle Amps

Idle Power

40%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

60%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

100%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

Idle Amps

Idle Power

RATED INPUT - SINGLE PHASE ONLY

K

Number

K1825-1

K1826-1

K2619-1

K1826-2

K2619-2

K1827-1

RATED OUTPUT - NEMA EW1 Class ll (40) K1825-1,K1826-1,-2, K2619-1.-2

Duty Cycle-Applications

40%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

60%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

100%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

Volts at Rated Amperes

31.0

16.1

29.0

15.4

28.0

14.8

Amps

275

255

225

200

200

150

*Shown on Front of this IM manual with Under-Cooler Cart and Advanced Control Panel (Refer to Optional Equipment)

#

Exceeds NEMA Unbalanced Load Specification comparable for Auto-Balance.

RATED POWER FACTOR (STICK) K1825-1,K1826-1 & K1826-2

.63 min.

.85 min.

K1827-1

.65 min.

.77 min.

R

R

NRTL/C

NRTL/C

IEC 60974-1

N80

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising